Gripsun Genesis Series 50 KW (GS-HAV-50K-100-H)

150% PV Input

 Massive 75kW solar capacity managed by four independent 30A MPPTs

50kW Three-Phase

 Pure sine wave 3-phase commercial output with 10ms UPS-grade switching.

Lithium-Ion

 100A ultra-fast charging optimized for high-voltage battery storage.

IP66 Protection

 Industrial-grade, fully sealed protection against heavy dust and rain.

Genesis Series 50kW (GS-HV-50K-100-H)

150% DC Oversizing

Connect up to 75kW of solar panels to maximize yield during low-light conditions and urban smog.

UPS-Grade Switching

<10ms transfer time ensures sensitive industrial equipment and servers never reboot during outages.

Fast 100A Charge

Rapidly recharge massive battery banks at 100A current, ensuring full storage during short grid windows.

Quad MPPT Architecture

4 independent 30A trackers handle modern high-wattage bifacial panels with zero current clipping.

Reliable

IP66 protection and extreme 60°C operating limit designed specifically for intense summers.

60kVA Generator Sync

Seamless integration with industrial generators for 100% power reliability during prolonged fuel/grid outages.

Genesis Series
GS-HV-50K-100-H
50 kW Three-Phase High-Voltage Hybrid Inverter
10 YEAR WARRANTY · 5+5 T&C APPLIED
PV Input
Recommended Max. Input Power75 kW
Start-up Voltage135 V
Max. DC Input Voltage1000 V
Rated DC Input Voltage620 V
MPPT Voltage Range200 ~ 850 V
No. of MPP Trackers4
No. of DC Inputs per MPPT2 + 2 + 2 + 2
Max. Input Current30 A × 4
Max. Short-Circuit Current40 A × 4
Battery Side
Battery TypeLithium Battery
Battery Voltage Range135 ~ 750 V
Maximum Charging / Discharge Current100 A
Grid Side
Rated Output Power50 kW
Max. Output Apparent Power55 kVA
Max. Input Apparent Power60 kVA
Max. Charging Power of Battery50 kW
Rated AC Voltage220/380, 230/400, 240/415, 3L/N/PE
Rated AC Frequency50 / 60 Hz
Max. Output Current83 A
Power Factor-0.8 lagging ~ 0.8 leading
Max. Total Harmonic Distortion< 3%
Back-up Side
Rated Output Power50 kW
Max. Output Apparent Power55 kVA
Max. Output Current83 A
UPS Switching Time10 ms
Rated Output Voltage3L/N/PE; 220/380V; 230/400V; 240/415V
Rated Output Frequency50 / 60 Hz
Voltage Harmonic Distortion< 3%
Generator Side
Maximum Apparent Input Power60 kVA
Rated Input Voltage3L/N/PE; 220/380V; 230/400V; 240/415V
Input Voltage Frequency50 / 60 Hz
Maximum Input Current90.9 A
Efficiency
Max. Efficiency98.8 %
European Efficiency98.3 %
Protection
Integrated ProtectionDC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Overvoltage Load Drop Protection, Ground Fault, Current Monitoring, Arc Fault Circuit Interrupter, Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch
Over Voltage CategoryPV: II  |  Main: III
General Data
Dimensions (W × H × D)800 × 620 × 300 mm
Weight72 kg
Protection DegreeIP66
Standby Self-Consumption< 40 W
TopologyTransformerless
Operating Temperature Range-30 ~ 60 °C
Relative Humidity0 ~ 100 %
Operating Altitude3000 m (> 3000 m derating)
CoolingSmart Fan Cooling
Noise Level< 65 dB
DisplayLED + LCD
CommunicationRS485 / CAN / WiFi / LAN