Gripsun Genesis Series 30 KW (GS-HV-30K-100-H)

150% PV Input

Massive 45kW solar capacity managed by four independent 30A MPPTs.

30kW Three-Phase

Pure sine wave 3-phase commercial output with 10ms UPS-grade switching.

Lithium-Ion

100A ultra-fast charging optimized for high-voltage battery storage.

IP66 Protection

Industrial-grade, fully sealed protection against heavy dust and rain.

Genesis Series 30kW (GS-HV-30K-100-H)

150% DC Oversizing

Connect up to 45kW of solar panels to maximize energy yield during cloudy days and heavy urban smog.

100A Ultra-Fast Charging

Rapidly recharge high-voltage lithium battery banks at 100A, ensuring full storage during short grid windows.

30kW Full Backup Output

Delivers an uncompromised three-phase 30kW power supply with 10ms UPS-grade switching for sensitive loads.

Quad MPPT Architecture

Four independent 30A trackers easily handle modern high-wattage bifacial panels with zero current clipping.

Extreme Heat & IP66

Fully sealed against heavy dust and monsoon rains, designed to operate flawlessly in intense 60°C Pakistani summers.

36kVA Generator Sync

Seamlessly integrates with heavy-duty industrial generators for reliable power management during prolonged outages.

Genesis Series
GS-HV-30K-100-H
30 kW Three-Phase High-Voltage Hybrid Inverter
10 YEAR WARRANTY · 5+5 T&C APPLIED

PV Input
Recommended Max. Input Power45 kW
Start-up Voltage135 V
Max. DC Input Voltage1000 V
Rated DC Input Voltage620 V
MPPT Voltage Range200 ~ 850 V
No. of MPP Trackers4
No. of DC Inputs per MPPT2 + 2 + 2 + 2
Max. Input Current30 A × 4
Max. Short-Circuit Current40 A × 4
Battery Side
Battery TypeLithium Battery
Battery Voltage Range135 ~ 750 V
Maximum Charging / Discharge Current100 A
Grid Side
Rated Output Power30 kW
Max. Output Apparent Power33 kVA
Max. Input Apparent Power36 kVA
Max. Charging Power of Battery30 kW
Rated AC Voltage220/380, 230/400, 240/415, 3L/N/PE
Rated AC Frequency50 / 60 Hz
Max. Output Current50 A
Power Factor-0.8 lagging ~ 0.8 leading
Max. Total Harmonic Distortion< 3%
Back-up Side
Rated Output Power30 kW
Max. Output Apparent Power33 kVA
Max. Output Current50 A
UPS Switching Time10 ms
Rated Output Voltage3L/N/PE; 220/380V; 230/400V; 240/415V
Rated Output Frequency50 / 60 Hz
Voltage Harmonic Distortion< 3%
Generator Side
Maximum Apparent Input Power36 kVA
Rated Input Voltage3L/N/PE; 220/380V; 230/400V; 240/415V
Input Voltage Frequency50 / 60 Hz
Maximum Input Current54.5 A
Efficiency
Max. Efficiency98.8 %
European Efficiency98.3 %
Protection
Integrated ProtectionDC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Overvoltage Load Drop Protection, Ground Fault, Current Monitoring, Arc Fault Circuit Interrupter, Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch
Over Voltage CategoryPV: II | Main: III
General Data
Dimensions (W × H × D)800 × 620 × 300 mm
Weight72 kg
Protection DegreeIP66
Standby Self-Consumption< 40 W
TopologyTransformerless
Operating Temperature Range-30 ~ 60 °C
Relative Humidity0 ~ 100 %
Operating Altitude3000 m (> 3000 m derating)
CoolingSmart Fan Cooling
Noise Level< 65 dB
DisplayLED + LCD
CommunicationRS485 / CAN / WiFi / LAN
Scroll to Top